Victron Multi RS Solar 48/6000/100-450/80 1 Tracker Hybrid Inverter/Charger
The Multi RS Solar 48/6000 is an Inverter Charger with a 450V Solar Charger on board. It also has a bi-directional DC-DC charger that charges the battery with excess solar power or converts power from the battery when required. The 4kWp Solar Charger can be daisy-chained to more Solar Chargers, with the possibility of synchronised charging; the Multi RS can also be connected to PV Inverters.
- 80 – 450VDC input
- Display. Data can also be read from a phone or Bluetooth device.
- Extendable PV capacity – both AC and DC coupled.
- Can be connected to a GX device via VE Can.
- Can be connected to a GlobalLink 520 vie VE Direct
Thanks to high-frequency technology and a new design the powerful Multi RS Solar 48/6000 With 450V/4000W PV input inverter weighs only 11kg. In addition to this, it has excellent efficiency, low standby power, and a very quiet operation. It's a great solution for tiny homes, cabins, and larger motorhomes through to small houses.
The display reads battery, inverter and solar parameters. The same parameters can be accessed with a smartphone or other Bluetooth enabled device, using the VictronConnect app.
Multi RS Solar 48/6000 Features:
Hybrid Inverter/Charger
The Multi RS Solar 48/6000 is a 48 V 6 kVA Inverter/Charger with 450 VDC 4 kWp PV input.
Combination of an inverter, AC charger, and Solar MPPT
The inverter produces a perfect sinewave and is able to supply high powered appliances. It is also bi-directional, charging the battery when excess solar power or AC supply is available, or converting from the battery when it is needed.
Wide MPPT voltage range
80 – 450 VDC, with a 120 VDC PV startup voltage.
Lightweight, efficient and quiet
Thanks to high-frequency technology and a new design this powerful inverter weighs only 11 kg. In addition to this, it has excellent efficiency, low standby power, and a very quiet operation.
Display, Bluetooth and VictronConnect app
The display reads battery, inverter and solar parameters. The same parameters can be accessed with a smartphone or other Bluetooth enabled device, using the VictronConnect app.
Extendable PV capacity, both AC-coupled and DC-coupled
The integrated 4 kWp PV capacity can be extended by adding Solar Chargers to the system, for example, Victrons Smart Solar Charger range, including the Smart Solar RS models. When connected in a VE.Can network, all battery charging will operate synchronously and coordinated. Alternatively, the PV capacity can be extended by installing PV Inverters, of which the output power will be automatically controlled by the integrated Frequency Shift Power Control.
Communication ports
VE.Can connection to a GX device for system monitoring, data logging, and remote firmware updates. VE.Direct connection to a GlobalLink 520 for remote data monitoring.
I/O Connections
Programmable Relay, temperature sensor and voltage sensor connections. The remote input can also be configured to accept the Victron smallBMS.
VRM Portal
When the Multi RS is connected to a GX device with an internet connection, you can access Victrons free remote monitoring website (VRM). This will display all your system data in a comprehensive graphical format. System settings can be changed remotely via the portal. Alarms can be received by e-mail.
Multi RS Solar | 48/6000 |
INVERTER | |
DC Input voltage range | 38 – 64 V (1) |
Output | Output voltage: 230 VAC ± 2 % Frequency: 50 Hz ± 0,1 % (2) |
Continuous output power at 25 °C | Increases linearly from 4800 W at 46 VDC to 5300 W at 52 VDC |
Continuous output power at 40 °C | 4500 W |
Continuous output power at 65 °C | 3000 W |
Peak power | 9 kW for 3 seconds |
Short-circuit output current | 74 A |
Max. inverter output AC overcurrent protection | 30 A |
Maximum efficiency | 96,5 % at 1 kW load 94 % at 5 kW load |
Zero load power | 20 W |
Low Battery shutdown | 37.2 V (adjustable) |
Low battery restart | 43.6 V (adjustable) |
SOLAR | |
Maximum DC voltage | 450 V |
Start-up voltage | 120 V |
MPPT operating voltage range | 80 – 450 V (3) |
Max operational PV input current | 18 A |
Max PV Short circuit current reverse polarity protection |
20 A |
Max PV short circuit current (Isc PV) | 30 A |
Earth leakage trip level | 30 mA |
Isolation fail level (detection before start-up) | 100 kΩ |
CHARGER | |
Programmable Charger voltage range (VDC) (5) | 36 – 62 V |
Charge voltage 'float' (VDC) | 55,2 V |
Maximum charge current | 100 A |
AC input current limit | 31 A |
Battery temperature sensor | Yes |
Maximum DC charging power | 4000 W |
GENERAL | |
Parallel and 3-phase operation | no |
Programmable relay (4) | Yes |
Protection (5) | a - g |
Data Communications Ports | VE.Direct port and VE.Can port (6) |
Bluetooth frequency | 2402 – 2480 MHz |
Bluetooth power | 4 dBm |
General purpose analogue/digital in port | Yes, 2x |
Remote on-off | Yes |
Operating temperature range | -40 to +65 °C (fan assisted cooling) |
Humidity (non-condensing) | max 95 % |
ENCLOSURE | |
Material & Colour | steel, blue RAL 5012 |
Protection category | IP21 |
Battery-connection | M8 bolts |
230 VAC-connection | Screw terminals 13 mm² (6 AWG) |
Weight | 11 kg |
Dimensions (hxwxd) | 425 x 440 x 125 mm |
STANDARDS | |
Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 |
Emission, Immunity |
EN 55014-1, EN 55014-2 |
1) Minimum start-up voltage is 41V. Inverter shutdown can be set as low as 32 VDC, but may shut down on low AC output voltage (due to load). Over-voltage disconnect is 65.5 V. Charger set-point can be set to max 62 V. The charge current derates above 57 V. 2) Can be adjusted to 60 Hz 3) MPPT operating range is also constrained by battery voltage - PV VOC should not exceed 8x battery float voltage, e.g. a 50 V battery voltage maximum should have 400 V maximum PV array. – see the product manual for further information. 4) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. DC rating: 4 A up to 35 VDC and 1 A up to 70 VDC 5) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) Solar earth leakage 6) Connection to a GX device (i.e. Cerbo GX) must be made via the VE.Can interface. The VE.Direct interface is for connection to the GlobalLink 520, and to a computer, using a VE.Direct to USB to cable. |
SKU | VIC.PMR482602000 |
Model # | PMR482602000 |
UPC/EAN | 8719076054474 |
Brand | Victron Energy |
Shipping Weight | 14.0000kg |
Shipping Width | 0.220m |
Shipping Height | 0.480m |
Shipping Length | 0.540m |
Shipping Cubic | 0.057024000m3 |
Unit Of Measure | ea |